Glycol Cooling Circulator for Fuel Battery Safe Testing Process at Low Temperature

Product Details
Customization: Available
After-sales Service: After-Sales Service Available
Warranty: 1 Year
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
5
Year of Establishment
2020-08-11
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Centralized control
  • Certifications
  • Company Profile
  • Other Products
  • Cooperation Cases
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
JEG Series
Type
Hydrogen Fuel Cell System Environmental Test Chamb
Test Region
Different Environmental Conditions
Application
Fuel Battery
Customized
Customized
Cooling Medium
50% Ethylene Glycol Aqueous Solution
Usage
Providing a Low-Temp Environment for Fuel Cell
Humidity Range
-40 ºC~Room Temperature
Flow Control Range
0L/Min~50L/Min
Transport Package
Wood Case
Specification
Internal volume: 60/72/100/120/150m3
Trademark
Jupiter
Origin
China

Product Description

JEG Series Glycol Cooling Circulator for Fuel Cell Safe Testing Process at Low Temperature
Product Description

Introduction

The ethylene glycol small cycle system can provide a temperature, flow rate, and pressure controllable cooling cycle circuit for the fuel cell during the low-temperature cold start testing process, enabling the fuel cell to start safely in a low-temperature environment, thereby evaluating the cold start performance, stability, and reliability of the fuel cell.

Application

Cooling stack: During low-temperature cold start, the stack is usually in a lower temperature state and needs to be rapidly heated to within the normal operating temperature range. The ethylene glycol small circulation system circulates the coolant (usually ethylene glycol aqueous solution) through the fuel cell stack to accelerate its heating and prevent overheating protection.

Temperature and related parameter control: The ethylene glycol small circulation system can control the temperature (flow rate, pressure) of the ethylene glycol solution entering the stack within the specified temperature range according to user needs, and then perform reliability verification or research and development data verification on the stack at different temperatures.

Composition & Control

The system components include: liquid storage container, high and low temperature circulation pump, pressure control device, pressure sensor, solenoid valve, temperature sensor, refrigeration heat exchanger, three-way directional valve, SUS316 pipeline system, and other multiple components. Before the low-temperature cold start, the storage container is located in the environmental chamber and is used to pre cool ethylene glycol to a temperature that matches the temperature of the environmental chamber. During the cold start process, the system precisely controls the flow rate, pressure, and temperature of ethylene glycol. When the coolant temperature rises to room temperature (a temperature that can be set), the system will automatically switch to the large circulation system at the end of the fuel cell stack for control.

Product Parameters
JEG Series Glycol Cooling Circulator
Cooling medium 50% ethylene glycol aqueous solution
Humidity range -40 ºC~room temperature
Flow control range 0 L/min~50 L/min
Quick cooling ability (optional function) Capable of rapid dehumidification, capable of removing ethylene glycol from the system within a specified time frame Reduce the liquid temperature from high humidity to the target set temperature, shorten the cold immersion time, and improve the measurement test efficiency.
Centralized control

Glycol Cooling Circulator for Fuel Battery Safe Testing Process at Low Temperature

 
Certifications

Glycol Cooling Circulator for Fuel Battery Safe Testing Process at Low Temperature

Company Profile

Glycol Cooling Circulator for Fuel Battery Safe Testing Process at Low TemperatureGlycol Cooling Circulator for Fuel Battery Safe Testing Process at Low TemperatureGlycol Cooling Circulator for Fuel Battery Safe Testing Process at Low TemperatureGlycol Cooling Circulator for Fuel Battery Safe Testing Process at Low Temperature

Other Products

Glycol Cooling Circulator for Fuel Battery Safe Testing Process at Low Temperature

Cooperation Cases

Glycol Cooling Circulator for Fuel Battery Safe Testing Process at Low Temperature

Packaging & Shipping
Glycol Cooling Circulator for Fuel Battery Safe Testing Process at Low TemperatureGlycol Cooling Circulator for Fuel Battery Safe Testing Process at Low Temperature

Send your message to this supplier