Jhm Series Hydrogen Fuel Cell System Battery Tester Environmental Test Chamber
| Customization: | Available |
|---|---|
| After-sales Service: | After-Sales Service Available |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Find Similar Products
Basic Info.
- Model NO.
- JHM Series
- Type
- Hydrogen Fuel Cell System Environmental Test Chamb
- Test Region
- Different Environmental Conditions
- Application
- Hydrogen Energy
- Customized
- Customized
- Maximum Fresh Air Volume
- 800/1200 M³/H
- Dimensions of High-Altitude Units (D*W*H
- 2800mm*1700mm*2500mm
- Temperature Range
- -40℃~90℃
- Heating Rate
- ≥ 1 ℃/Min
- Transport Package
- Wood Case
- Specification
- Internal volume: 60/72/100/120/150m3
- Trademark
- Jupiter
- Origin
- China
Product Description
Introduction
The reliability and performance of hydrogen fuel cell systems play a crucial role in promoting the development of hydrogen energy technology. In order to ensure the stable operation of various series of hydrogen fuel cell systems under different environmental conditions, our company has developed the UC series walk-in hydrogen fuel cell system environmental test chamber.
Advanced equipment designed specifically for hydrogen fuel cell systems can undergo environmental simulation tests in accordance with standards such as GB/24554-2009.
The experimental module includes core components such as the cabin, refrigeration unit, oil heating unit, high-altitude simulation unit, and fresh air unit, ensuring precise environmental control and simulation of the hydrogen fuel cell system during the testing process. It has the ability to simulate the environment under a combination of multiple factors such as temperature, humidity, and low air pressure in the natural environment (requiring an optional high-altitude simulation system). After integrating the software and hardware systems with the test bench, the working status of the test chamber can be remotely monitored and controlled through the main control system of the test bench. Parameters such as temperature, humidity, and height can be individually programmed and controlled, or linked and controlled through the main control program of the test bench to ensure the accuracy and controllability of the test process.
Solutions
- Provide two professional solutions for indoor and outdoor heat dissipation to ensure accurate and reliable temperature control during the testing process.
- The software control system equipped with independent intellectual property rights adopts CFD simulation air duct method to respond more quickly to the coupling effect of multiple physical fields, further ensuring that the tolerance is controlled within the allowable range of test standards.
- The integration of software and hardware systems enables remote monitoring and control, improving the convenience and efficiency of experiments.
Primary Purpose
- Low temperature test (low-temperature storage, starting, performance)
- High temperature test (high temperature storage, starting, performance)
- Damp heat test (high temperature and humid heat)
- Temperature altitude test (pressure simulation)
- Cold start test of hydrogen fuel cell system at -30ºC
| JHM Series (Internal Heat Dissipation) Hydrogen Fuel Cell System Environmental Test Chamber | |||||
| Model | JHM60T-I/LP(WP) | JHM70T-I/LP(WP) | JHM100T-I/LP(WP) | JHM120T-I/LP(WP) | JHM150T-I/LP(WP) |
| Adaptation system | 120KW | 150KW | 200KW | 250KW | 300KW |
| Hydrogen air pre cooling device | JHP3-T | JHP4-T | JHP5-T | JHP6-T | |
| Maximum fresh air volume | 800m³/h | 1200m³/h | |||
| Internal volume | 60m³ | 72m³ | 100m³ | 120m³ | 150m³ |
| External dimensions of the cabin (D*W*H) | 5700mm*4300mm *4300mm |
6500mm*4300mm *4300mm |
6800mm*5300mm *4700mm |
7800mm*5300mm *4700mm |
8050mm*6300mm *4700mm |
| Refrigeration unit size (D*W*H) |
2950mm*1850mm *2400mm*2 |
2950mm*1850mm*2400mm*2 | 2950mm*1850mm*2400mm*2 | 2950mm*1850mm*2400mm*3 | 2950mm*1850mm*2400mm*3 |
| Dimensions of high-altitude units (D*W*H) | 2800mm*1700mm*2500mm | ||||
| Size of fresh air unit (D*W*H) | 3500mm*1100mm*1900mm | 3500mm*1200mm*2000mm | |||
| Hydrogen pre cooling size (D*W*H) | 1800mm*1000mm*2600mm | 2250mm*1250mm*2600mm | |||
| General Technical Indicators | |||||
| 1.1 Temperature range | -40ºC~90ºC | ||||
| 1.2 Heating rate | ≥ 1 ºC/min (-40 ºC~+90 ºC range Average throughout the entire process, with hydrogen fuel cell system and tooling, the system does not dissipate heat. | ||||
| 1.3 Cooling rate | ≥ 1 ºC/min (-40 ºC~+90 ºC range Average throughout the entire process, with hydrogen fuel cell system and tooling, the system does not dissipate heat. | ||||
| 1.4 Temperature deviation | ≤ ± 0.2 ° C | ||||
| 1.5 Temperature fluctuation | ≤ ± 0.5 ° C (Static without thermal load) ≤ 2.0 ° C (Dynamic test condition) |
||||
| 1.6 Temperature uniformity | ≤ 2.0 ºC (Unload, atmospheric, static) | ||||
| Humidity range | 20% RH~95%RH | ||||
| Temperature range during humidity test |
20ºC~85°C | ||||
| Humidity deviation | (Humidity>75% RH)+2~-3% RH | ||||
| Pipeline pressure range | Atmospheric pressure~40kPa (approximately 6100m above sea level) | ||||
| Pipeline pressure accuracy | 2KPa (loaded, dynamic for 3 minutes, with a maximum of ≤ ± 5KPa within 3 minutes) | ||||
| Pipeline pressure reduction rate | Atmospheric pressure~40kpa ≤ 10min | ||||
| Pipeline pressure recovery rate | 40kPa~atmospheric pressure ≤ 10min | ||||
| Pipeline pressure deviation | ≤±2KPa | ||||
| JHM Series (External Heat Dissipation) Hydrogen Fuel Cell System Environmental Test Chamber | |||||
| Model | JHM15T-O/LP(WP) | JHM24T-O/LP(WP) | |||
| Adaptation system | 120KW | 150KW | 200KW | 250KW | 300KW |
| Hydrogen air pre cooling device | HY3-TC | JHP4-T | JHP5-T | JHP6-T | |
| Maximum fresh air volume | 800m³/h | 1200m³/h | |||
| Internal volume | 15m³ | 24m³ | |||
| External dimensions of the cabin (D*W*H) |
3800mm*2800mm*3100mm | 4500mm*3300mm *3200mm |
|||
| Refrigeration unit size (D*W*H) |
2200mm*1200mm *2000mm |
2200mm*1400mm*2000m | 2950mm*1850mm *2400mm |
||
| Dimensions of high-altitude units (D*W*H) |
2800mm*1700mm*2500mm | ||||
| Size of fresh air unit (D*W*H) |
3500mm*1100mm*1900mm | 3500mm*1200mm*2000mm | |||
| Hydrogen pre cooling size (D*W*H) |
1800mm*1000mm*2600mm | 2400mm*1250mm*2600mm | |||
| General Technical Indicators | |||||
| Temperature range | -40ºC~90ºC | ||||
| Heating rate | ≥ 1 ºC/min (-40 ºC~+90 ºC range Average throughout the entire process, with hydrogen fuel cell system and tooling, the system does not dissipate heat. | ||||
| Cooling rate | ≥ 1 ºC/min (-40 ºC~+90 ºC range Average throughout the entire process, with hydrogen fuel cell system and tooling, the system does not dissipate heat. | ||||
| Temperature deviation | ≤ ± 0.2 ° C | ||||
| Temperature fluctuation | ≤ ± 0.5 ° C (Static without thermal load) ≤ 2.0 ° C (Dynamic test condition) |
||||
| Temperature uniformity | ≤ 2.0 ºC (Unload, atmospheric, static) | ||||
| Humidity range | 20% RH~95%RH | ||||
| Temperature range during humidity test |
20ºC~85°C | ||||
| Humidity deviation | (Humidity>75% RH)+2~-3% RH (Humidity<75% RH)± 5% RH |
||||
| Pipeline pressure range | Atmospheric pressure~40kPa (approximately 6100m above sea level) | ||||
| Pipeline pressure accuracy | 2KPa (loaded, dynamic for 3 minutes, with a maximum of ≤ ± 5KPa within 3 minutes) | ||||
| Pipeline pressure reduction rate | Atmospheric pressure~40kpa ≤ 10min | ||||
| Pipeline pressure recovery rate | 40kPa~atmospheric pressure ≤ 10min | ||||
| Pipeline pressure deviation | ≤±2KPa | ||||









Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Hydrogen Fuel Cell Test Machine
- Fuel Cell Test System