Temperature Shock Chamber with Three Chambers
Product Description
Introduction
Adapted to determine the clean materials, electronics, electrical products, components equipment, etc. according to the national standard, special standard requirements when subjected to abrupt changes in the ambient air temperature (temperature shocks) when, whether to generate physical damage or performance degradation.
Feature
- 3 cases of equipment is divided into: high temperature, low temperature area, test area, test the product in the test area, impact at high temperature or low temperature zone temperature impact test area, test the product for static type.
- The touch controller interface, operation easy.
- Impact mode application wind path switching mode will import test temperature zone, cold and hot shock tests.
- High temperature shock or the impact of low temperature and maximum time of up to 999 h, the maximum cycle of up to 9999 times.
- System can make automatic cycle official holding or manual selective shock impact and can be set two areas or areas and cold heat impact and inception.
- Cooling binary refrigeration system, cooling rapidly, for water-cooled cooling way.
- Can perform impact test at room temperature to meet the standard and test method: GJB150.5 temperature impact test; GJB360.7 temperature impact test; GB / 2423.22 temperature impact test.
Product Parameters
Parameters for all models
Temperature Shock Chamber(Three Chamber) |
Model |
JTS72F-B/S/E |
JTS100F-B/S/E |
JTS150F-B/S/E |
JTS200F-B/S/E |
JTS320F-B/S/E |
JTS500F-B/S/E |
JTS1000F-B/S/E |
Nominal inside volume(L) |
72L |
100L |
150L |
200L |
320L |
500L |
1000L |
Performance parameter |
Heat storage chamber |
Temperature exposure range |
+50ºC~+150ºC |
Upper limit of preheating temperature |
200ºC |
Heating time |
RT~+200ºC, B type: ≤50 min; S type: ≤40 min; E type: ≤30 min |
Cold storage chamber |
Temperature exposure range |
B type: 0~-40ºC; S type: 0~-55ºC; E type: 0~-65ºC |
Lower limit of pre cooling temperature |
-75ºC |
Cooling time |
RT~-70ºC, B type: ≤60 min; S type: ≤50 min; E type: ≤40 min |
Chamber |
Temperature shock range |
B type: -40ºC~+150ºC; S type: -55ºC~+150ºC; E type: -65ºC~+150ºC |
Temperature fluctuation |
≤±0.5 |
Temperature uniformity |
≤2ºC |
Temperature deviation |
≤±2ºC |
Transfer time |
≤10s |
Temperature recovery time |
≤5min |
Load (steel) |
3kg |
5kg |
7kg |
10kg |
15kg |
20kg |
40kg |
Optional: High and low temperature test function |
Temperature range |
-65ºC~+150ºC |
Temperature rise and fall rate |
B type nearly 2ºC/min, S type nearly 3ºC/min, E nearly 4ºC/min |
Remarks |
Above indicators are measured in no load at ambient temperature of 20±2°C(According to GB/T 5170.2-2017) |
Internal dimensions |
D |
400 |
500 |
500 |
600 |
700 |
800 |
1000 |
W |
450 |
500 |
600 |
600 |
700 |
900 |
1000 |
H |
400 |
400 |
500 |
550 |
650 |
700 |
1000 |
External dimensions |
D |
2150 |
2300 |
2300 |
2500 |
2600 |
2800 |
3600 |
W |
1450 |
1500 |
1600 |
1600 |
1700 |
1900 |
2550 |
H |
2000 |
2000 |
2200 |
2300 |
2500 |
2620 |
2250 |
Caster |
4 -6 standard casters |
/ |
Test hole |
Φ50 |
Φ100 |
Stainless steel shelf (2 pcs in standard configuration) |
Bearing 20kg/pc |
Bearing 30kg/pc |
Bearing 50kg/pc |
Using environment temperature |
0~+40ºC |
Shell |
Sprayed steel plate |
Interior |
SUS 304 stainless steel |
Cooling mode |
water-cooling, (water temperature 7~28ºC, hydraulic pressure 0.2~0.4Mpa, to ensure cooling performance) |
Controller |
7′ Color touch screen Controller |
Communication function |
RS485 or standard RJ45 network interface, standard USB interface |
Installed capacity(kw)(L/S/E) |
13/17/22 |
17/22/29 |
23/28/34 |
27/33/40 |
33/40/50 |
50/60/75 |
75/90/110 |
Weight(kg) |
800 |
1300 |
1600 |
1900 |
2500 |
2800 |
3600 |
Meet the testing method |
GJB150.5-2009, GB/T2423-2008.
The optional high and low temperature test function also meets GB2423.1-2008, GB2423.2-2008, GJB150.3-2009, GJB150.4-2009. |
Safety precautions |
Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Heater short circuit protection, refrigeration unit overpressure/ overload/ oil shortage protection; Humidifier fault protection; Overload/ overheating protection for blower motor, overcurrent protection and leakage protection for control board; Cooling water shortage protection, gas source undervoltage protection, etc. |
Optional |
1.Optional high and low temperature testing function; 2. Optional special test holes and special shelves; 3. Optional liquid nitrogen function. |
Centralized control

Certifications

Company Profile




Other Products

Cooperation Cases

Packaging & Shipping