Customization: | Available |
---|---|
After-sales Service: | After-Sales Service Available |
Power Supply: | 380 V +/- 10% 50Hz 3/N/PE |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
JC-Series High and Low Temperature (Humidity) Test Chamber | ||||||
Model | JC330(C) | JC610(C) | JC1000(C) | JC1500(C) | JC2000(C) | |
Nominal inside volume(L) | 335 | 605 | 1000 | 1530 | 2000 | |
Internal dimension(mm) | D | 760 | 795 | 960 | 1470 | 1670 |
W | 585 | 800 | 1100 | 1100 | 1100 | |
H | 750 | 950 | 950 | 950 | 1100 | |
External dimension(mm) | D | 1820 | 1850 | 2000 | 2525 | 2700 |
W | 880 | 1100 | 1450 | 1450 | 1430 | |
H | 1950 | 2230 | 2230 | 2230 | 2400 |
mance Parameters | Minimum temperature ºC | End with C: minimum temperature -70ºC; without C: minimum temperature -40ºC | ||||
Maximum temperature ºC | +180ºC(Maximum temperature can be up to 220ºC according to user's actual demand) | |||||
Temperature fluctuation ºC | ±0.1ºC~±0.5ºC | |||||
Temperature uniformity ºC | <=2ºC(≤150ºC) | |||||
Temperature deviation ºC | <=±2ºC | |||||
Temperature rise rate ºC/min | 4.0 | 6.0 | 4.0 | 4.0 | 3.0 | |
Cooling rate ºC/min | 3.5 | 2.6 | 2.8 | 2.5 | 2.0 | |
Humidity range %R.H. | 10%~+98% R.H. (humidity operating range +10°C~+95°C) | |||||
Dew point temperature range ºC | 0~94ºC | |||||
Humidity deviation %R.H. | -3%R.H.~+2%R.H. | |||||
Humidity fluctuation %R.H. | ≤ ± 3 %R.H. | |||||
Test method | The above indexes are measured at no load, ambient temperature 20±2ºC (according to GB/T 5170.2-2017) Rate assessment range:Tmin-Tmax, according to IEC60068-3-5, measured at the air outlet, empty box indicator. Temperature and humidity performance test according to standard IEC60068-3-5, the sensor is placed at the air outlet of the air handling unit. |
Meets standards | 1.Low Temperature Test: IEC 60068-2-1; IEC 60721-4; MIL-STD-810 G, Meth.502.5; GB/T2423.1 TestA 2.High temperature test: IEC 60068-2-2; IEC 60721-4; MIL-STD-202 G, Meth.108A; MIL-STD-810 G, Meth.501.5; MIL-STD-883 J, Meth.1008.2; GB/T 2423.2 Test B 3.Temperature and humidity tests: IEC 60068-2-67; IEC 60068-2-78; IEC 60721-4; ISO 16750-4, Damp heat steady; GB/T 2423.3 Test Cab; GB/T 2423.4 Test Db -Test cycle-Variant 1 and Variant 2; GB/T 2423.50 Test Cy; lEC 60068-2-30 Test Db -Test cycle -Variant 1 and Variant 2 | |||||
Thermal compensation capacity | 1500-3000 W | |||||
Cooling method | 400W (temperature 25°C to 90°C, humidity not exceeding 90%) |