• Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
  • Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
  • Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
  • Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
  • Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
  • Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven

Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven

After-sales Service: Response Within 24 Hour
Warranty: 1 Year
Application: Industry, Lab
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven pictures & photos
Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
US $5,000 / set
Min. Order: 1 set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
ADV
Customized
Customized
Certification
CE, ISO, RoHS
Material
Stainless Steel
Type
Incubator
Temperature Ran-70ge
Rt~+300
Voltage
380V/220V
Inner Box Size
600 * 500 * 1000
Way to Work
Adv: Program Run/Value Run Adl: Value Run
Transport Package
Wooden Package
Specification
customized
Trademark
ATEC
Origin
China
HS Code
8479899990

Packaging & Delivery

Package Size
80.00cm * 90.00cm * 170.00cm
Package Gross Weight
300.000kg

Product Description

Drug Stability Test Chamber

Application:
The Drug Stability Test Chamber has a precise temperature and humidity control system. It provides various environmental simulation conditions required for industrial research and biotechnology testing. Therefore, it can be widely used in sterile tests and stability inspections for pharmaceuticals, textiles, and food processing. As well as testing of raw material properties, product packaging, and product life of industrial products.
Feature:
Drug Stability Test Chamber designed with 100L, 250L, 400L internal capacity volume. It offers 30 to 95 % RH humidity range and temperature ranges from 15ºC to 70ºC. Designed to simulate constant climatic conditions for testing a wide variety of pharmaceutical raw Drug material or finished Drug products for their quality, performance, shelf life and stability. It features conductive film located on the interior glass (of double layer 8 cm thick insulation glass) to prevent window frosting, built-in LED light for the work room lighting to clearly observe samples. A good temperature humidity chamber is essential for evaluating potential success or failure of a product in the field.
Main technical parameters]
Type no. ADV100
ADL100
ADV150
ADL150
ADV250
ADL250
ADV500
ADL500
ADV1000
ADL1000
Temperature range Room temperature +10 C to 250 C Room temperature +10ºC ~ 300ºC
Maximum temperature arrival time Approx.70min
Nominal content product 80L 150L 300L 500L 1000L
Inner box size mm
Width W x depth D x height H
400 * 400 * 500 600 * 500 * 500 600 * 500 * 1000 800 * 700 * 900 1000 * 1000 * 1000
External dimensions MM
Width W x depth D x height H
510 * 550 * 870 710 * 650 * 870 710 * 650 * 1610 910 * 860 * 1610 1200 * 1650 * 1500
Way to work ADV: Program run/Value run ADL: Value run
The weight of the About 60 kg About 75 kg About 120 kg About 180 kg About 300 kg
The power capacity AC220V 6.0 A AC220V 7.5 A AC220V 15A AC380V 20A AC380V 18A




 
1. Product name and purpose
1.1 Product Name

1.2 use


1.3 Execution Standards
Air supply drying oven with fixed temperature

Suitable for electronic semiconductor, liquid crystal, precision instruments, materials manufacturing, life science and other aspects of baking, drying, curing and constant temperature test.

GB/T 30435-2013 electric heating drying oven and electric heating blast drying oven
2. Circulation mode Forced air circulation
3 Sample limit Test or storage of flammable, explosive, volatile material samples
corrosive material sample test or storage
Testing or storage of biological samples
Strong electromagnetic emission source test or storage of samples
4.Model naming method











 
ADV - - -    
           
        Model code: 0: Standard
          1: First change
        Volume code: 10:8 0 l
          0 l"
          "0 l
Area 0 l
100:1000L
        Shape Code: 1: Desktop type
          2: Floor type
        Product series code: ADV: Standard type, program running/fixed value running
ADL: Universal, constant run
5. Volume, size and weight  
5.1 Standard volume of contents

5.2 Inner dimensions

5.3External Dimensions

5.4 weight
See [Main Technical parameters]

See [Main Technical Parameters]

See [Main Technical Parameters]

See [Main Technical Parameters]
Performance of 6.
6.1Test environmental conditions

6.2 Test Methods

6.3Temperature Range

6.4Temperature fluctuation
6.5 Temperature uniformity

6.6 Heating Time

6.7 Temperature Control
The ambient temperature is 23 ° C ±5 ° C, the humidity is 65%±20%, and there is no sample in the device

GB/T 30435-2013 electric heating drying oven and electric heating blast drying oven

See [Main technical parameters]

±0.5 ° C (no-load test)

±2.5% (no-load test)


See [Main Technical parameters]

Use armoured SUS304 stainless steel heater as a heating element, intelligent temperature control instrument for real-time sampling box temperature, compared with the temperature on the controller set point, the PID arithmetic, to control the on-off time of SSR, so as to control the output of the heater heat, at the same time combined with forced air circulation way, achieve constant temperature in the oven.
7. Structural features  
7.1 Exterior materials

7.2 Interior materials


7.3 Heat break material

7.4 the door

7.5 the door seal

7.6 observation window



7.7 castor


7.8 vent



7.9 lead hole


7.10 Shed board load bearing



7.11 Number of shed support sections






7.11 Distance between shelter reception segments

7.12 the heater






7.13 the fan
 
Cold rolled steel plate, surface electrostatic spray treatment, color RAL9003 signal white

ADV series: SUS304 stainless steel plate;
ADL series: SUS201 stainless steel plate;

High density aluminum silicate fiber cotton

Single door with hinge on left and handle on right

Seal with Japanese-made custom foam silicone seal strips













 
ADV100/150 ADL100/150 ADV250/500/1000 ADL250/500/1000
3 layers of toughened glass There is no window There is no window

ADV100/150 ADL100/150 ADV250/500/1000 ADL250/500/1000
No casters, 4 rubber support feet Four castor

ADV100/150 ADL100/150 ADV250/500 ADL250/500 ADV1000 ADL1000
φ30mm×2 body above φ30mm×2 back of the body φ60mm above the body

ADV100/150/250/500 ADL100/150/250/500 ADV1000 ADL1000
φ30mm×1 Right side of the body φ50mm×1 right side of the body

ADV100/150/250 ADL100/150/250 ADV500/1000 ADL500/1000
15 kg/layer 30 kg/layer

ADV100
ADL100
ADV150
ADL150
ADV250
ADL250
ADV500
ADL500
ADV1000
ADL1000
Paragraph 13 Paragraph 13 Section 29 25 period Section 29

30mm

Stainless steel tube heater
ADV100
ADL100
ADV150
ADL150
ADV250
ADL250
ADV500
ADL500
ADV1000
ADL1000
1.2 kW 1.5 kW 1.5 kW x 2 2 kw x 2 2 kw x3
ADV100
ADL100
ADV150
ADL150
ADV250
ADL250
ADV500
ADL500
ADV1000
ADL1000
25W 25W 40W 40 w x 2 180 w * 2
8 Control system  
8.1 temperature modulator














8.2 Temperature control mode

8.3 Temperature setting Mode

8.4 Temperature Setting Method

8.5 Operation Function

8.6 Program Mode

8.7 Accessory Features

8.8 Heater loop control

8.9 Temperature overrise preventer

8.10 the sensor


8.11 the power cord
 
   

Imported intelligent temperature controller
PID control


Special operation setting menu and key for digital setting


4 section LED digital display


ADV series: fixed value run, program run, ADL series: fixed value run


2 sets, 30 segments (ADV series only)

Temperature compensation function, key lock function, PID self-tuning function

SSR (solid state relay) contactless isoperiodic pulse width tuning


It is used to prevent abnormal overrise of temperature


Both the temperature regulator and the overrise preventer use K-type thermocouples

Adv100/150, ADL100/150: about 2m long with plug
ADV250//500/1000, ADL250/500/1000: about 3m long wiring
9. Safety device Self-diagnosis function (temperature sensor abnormality, heater disconnect, SSR short circuit, automatic overrise prevention function), lock key function, overrise prevention device, leakage circuit breaker
10. Accessories  
10.1 Instruction Manual

10.2 shed board
Instructions for detailed use of the product
 
ADV100
ADL100
ADV150
ADL150
ADV250
ADL250
ADV500
ADL500
ADV1000
ADL1000
2 pieces 2 pieces 4 pieces 2 pieces 2 pieces
11 Optional accessories  
11.1 stand

11.2 shed board

11.3 lead hole

11.4 External communication function

11.5 Overlapping shelf
The bottom surface is fixed with ADV100/ADV150;No ADV250/500/1000

For when additional ADV250,500/1000 is required

Inner diameter 25/50mm right side of body

RS485

 
 
   

 
Transport of 12.  
12.1 way

12.2 Packing Materials
Integral, integral transport

Packed in wooden cases
13. Service conditions  
13.1 site






13.2 Environmental conditions



13.3 Power capacity

13.4 Requirements for the storage environment
The floor is level and well ventilated
There is no strong vibration around the equipment
There is no strong electromagnetic field around the equipment
No flammable, explosive, corrosive substances, or dust are found around the device
The ground bearing capacity: not less than 800kg/m2
Appropriate space for use and maintenance should be left around the equipment

Temperature: 0ºC ~ 40ºC
Relative humidity: 85%
Air pressure: 86kPa ~ 106kPa

See [Main technical parameters]

When the equipment is not working, the ambient temperature should be kept within 0 ° C to +35 ° C
15.After-sales service
15.1 the quality assurance period


15.2 Out of warranty period

15.3 Timeliness of service
Within 12 months from the date of acceptance and signature confirmation, the company shall be responsible for free maintenance of faults caused by manufacturing reasons, but not including equipment damage caused by human reasons;

For equipment maintenance outside the warranty period, only the cost of accessories will be charged and lifelong technical support will be provided;

ATEC company has a spare parts library, can quickly provide a variety of parts, outside the warranty period, only the cost charge.After the seller receives the buyer's fault notice, guarantee to respond within 1 hour, and strive for 48 hours to troubleshoot;
14. The appended drawings  

Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory OvenHot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory OvenHot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory OvenHot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory OvenHot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
Big Reasons to Buy

 

1. We appreciate you, the customer, and we always treat our customers with the greatest consideration and courtesy.


2. We'll be here tomorrow. Our business has been headquartered in Chongqing, Guangzhou for over twenty years. We are only one public company of environment test equipment manufacturers in China.


3. We'll do our best to remedy any problem you might have with a purchase. We are old fashioned in our customer service; We believe we have an obligation to give you our best if you purchase from us.

4. Your order will be filled accurately and shipped promptly. We have thousands of parts in stock. We have been selling by email order for over fifteen years.


5. You won't pay too much. Our volume buying and low overheads assures you of a low price and top quality new products.

 
 
Our Services
 
 
1,Pre-sales service
 
Before the purchase, our company will provide customers with detailed product-related information, and welcome you to visit the company and check the goods.
 
2,After-sales service
 
After the completion of the transaction, our company will be arranged different after-sales service according to the ease of the goods , and even arrange work engineers on-site service.
 
3,Warranty period
 
Our product warranty is 12 months and we are committed to responding within 48 hours of the problem, providing a solution.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven pictures & photos
Hot Air Drug Medicine Stability Test Drying Oven Medical Equipment Laboratory Oven
US $5,000 / set
Min. Order: 1 set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
5
Year of Establishment
2020-08-11