Customization: | Available |
---|---|
After-sales Service: | After-Sales Service Available |
Power Supply: | 380V +/- 10%/50Hz +/- 1(3p+N+G) |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High - Low Temperature ( Humidity ) Chamber | |||||||||
Madel Number | CH100(TC) | CH160(TC) | CH250(TC) | CH340(TC) | CH600(TC) | CH1000(TC) | CH1600(TC) | CH2000(TC) | |
Interior capacity(L) | 100L | 160L | 250L | 340L | 600L | 1000L | 1600L | 2000L | |
Performance | Temperature Range | C: -70ºC ~ +150ºC(CH100C: -60ºC ~ +150ºC); Empty: -40ºC ~ +150ºC; T: Only temperature, Empty: temperature and humidity | |||||||
Temperature Fluctuation | ±0.5ºC | ||||||||
Temperature Deviation | ±2ºC | ||||||||
Temperature Uniformity | 2ºC | ||||||||
Humidity Deviation | -3~+2%R.H.(>75%R.H.),±5%R.H.(≤75%R.H.) | ||||||||
Heating Rate (average value) | 2ºC/min | 3ºC/min | 2.5ºC/min | 2.5ºC/min | |||||
Cooling Rate (average value | 1.5ºC/min | 2ºC/min | 1.8ºC/min | 1.5ºC/min | |||||
Remark | Above measured at ambient 20±2ºC,no load,heating/cooling rate moasured within+80/-30C and +85/-55ºC |
Interior Size (mm) | D | 400 | 500 | 535 | 700 | 750 | 1000 | 1000 | 1100 |
W | 500 | 560 | 600 | 650 | 850 | 1000 | 1000 | 1000 | |
H | 500 | 600 | 750 | 750 | 900 | 1000 | 1600 | 1800 | |
Exterior Size (mm) | D | 1250 | 1100 | 1510 | 1680 | 1750 | 2000 | 2100 | 2300 |
W | 750 | 810 | 850 | 900 | 1100 | 1250 | 1250 | 1250 | |
H | 1650 | 1760 | 1580 | 1650 | 1880 | 1980 | 2000 | 2200 | |
Casters | 4 casters(exterior size above not include casters,casters increased 50-100mm) | ||||||||
Inspection window | 450×450 with heating device to prevent condensation and frost | ||||||||
Cable Port | φ80×1,on the right side of chamber(facing door) | ||||||||
Stainless Steel Shelf(2pcs) | Load bearing 20kg/each | Load bearing35kg/each | |||||||
Internal Lighting | 35W/12V | 2*35W/12V |
Sub-Controller | Energy saving method | Independent PID regulation of cooling and heating (i.e.heating no refrigeration, refrigeration no heating, saving 30% than BTC) | |||||||
Heating | Electrical heating(3 kinds of overtemperature protection) | ||||||||
Humidification | Steam humidification(water consumption 0-500ml/day) | ||||||||
Refrigerating | Imported brand compressor (TECUMSEH/COPELAND/BITZER) | ||||||||
Refrigerant | Environmentally friendly refrigerants R404A:CH100/CH160/CH250/CH340/CH600/CH1000 R404A+R23:other | ||||||||
Condenser | Air-cooled (water-cooled optional, water temperature range:10~30ºC, pressure range:0.2 ~0.5Mpa) | ||||||||
Controller | Controller | 7' Color touch screen, resolution:800x480, on the top of window | |||||||
Control Mode | Program and fixed value | ||||||||
Program capacity | 100×200, cycle, skip, maintain, link | ||||||||
Sensor | PT100 | ||||||||
Communication | RS485 or LAN interface,USB interface as standard configuration,with host software | ||||||||
Curve function | auto recorded by touch screen | ||||||||
Power supply | 380V±10%/50HZ±1(3P+N+G) | ||||||||
Rated current(A)(-/-C) | 12/15 | 13/16 | 15/20 | 15/20 | 22/28 | 25/32 | 26/35 | 29/38 | |
Installed power(kw)(-/-C) | 4.8/5.5 | 5.2/7 | 6.3/8.5 | 6.3/8.5 | 10/13 | 13/17 | 15/19 | 16/20 | |
Weight (kg)w(-/-C) | 210/250 | 280/330 | 330/380 | 400/450 | 620/680 | 900/960 | 1300/1400 | 1600/1700 |